27
INSERTPELLETSTOVEINSTALLATION‐continued
MinimumClearancetoCombustiblesandFloorProtection
A:Sidewall:16”tosideofappliance
B:TopTrim:5”abovetopofappliance
C:Sidetrim:10.5”tosideofappliance
D:Mantle:10”abovetopofappliance
FloorProtection
WheninMASONRYfireplaces,use½inchthicknoncombustiblematerial.
WheninFactorybuiltfireplaces,usea1inch,noncombustiblesurfacewithakfactorof0.84.Formultiplelayers,
addRvaluesofeachlayertodeterminetheoverallRvalue.TheRvaluefortherequired
boardis1.2.
ConvertspecificationtoRvalue:
kfactorisgivenwitharequiredthickness(T)ininches:R=1/kxT.TheCfactorisgiven:R=1/C
Example:
Ifthefloorprotectoris4”brickwithaCfactorof1.25 over1/8”mineralboardwitha“k”factorof
0.29thetotalR
valueofthesystemis:
4”brickC=1.25,R=1/1.25=0.8
1/8”mineralboardK=0.29,R=1/0.29x0.125=0.431
TotalR=Rbrick+Rmineral=0.8+0.431=1.231
TotalRisgreaterthan1.2, thesystemisacceptable.
