INSTALLINGYOURROOMHEATER‐continued
HORIZONTALEXHAUSTVENTINSTALLATION
1. Locate your pellet stove inalocation which meets therequirementsofthis manual, butinanarea
whereitdoesnotinterferewiththehouseframing,wiring,etc.
2. Installanoncombustiblehearthpadunderneaththepelletstove.Thispadshouldextendatleast6”
(152mm)in
frontoftheunit.
3. Placethepelletstoveapproximately15”(381mm)awayfromtheinteriorwall.
4. Locatethecenteroftheexhaustpipeofyourunit.Thispointshouldthenbeextendedtotheinterior
wallofyour house.Once youhavelocatedthecenterpoint,onthe interior wall,cuta 7” (175mm)
diameterholethroughthewall.
5. Thenextstepistoinstallthe wallthimble,refertotheinstructionswhichcomewiththewallthimble
forthisstep.
6. Install the appropriate length of exhaust vent pipe into the wall thimble. See step 11 when
determiningthecorrectlengthofexhaustventtouse.
7. OutsideFreshAirisMandatorywheninstallingthispelletstoveroomheaterinairtighthomesand
mobilehomes.Besurethattheoutsideairventhasanapprovedcaponittopreventrodentsfrom
entering.Besuretoinstallinlocationthatwon’tbecomeblockedwithsnow,etc.
8. The air intake pipe is equipped with a butterfly valve that is preset to maximum air intake.For
optimum operating efficiency you may calibrate the butterfly valve to provide less intake air. (See
Figure 7)Caution: Too much restriction on the intake air will cause dirtier burn, therefore, will
requiremorefrequentcleaning.
9. Connecttheexhaustventpipetotheexhaustoutletofyourpelletstove.
10. Secure all vent joint connections with 3 screws. Seal the exhaust vent joint connections with high
temperaturesiliconesealant.
11. Push the unit straight back to the interior wall, being sure to maintain the minimum clearances to
combustibles 6” (152mm) to the back of the unit.Seal the annular space of the wall thimble and
aroundtheventpipewithhightemperaturesiliconesealant.
12. Theexhaustventpipemustextendatleast12”(300mm)outpasttheexteriorwall.Sealtheannular
space
ofthewallthimbleandaroundtheventpipewithhightemperaturesiliconesealant.
13. Install an approved horizontal termination cap or if necessary install a 90° elbow and appropriate
lengthofverticalventing.Anapprovedverticalventcapisrecommended.